Olympus CV-170 vs Olympus OTV-S190 / CLV-S190 – Endoscopy System Comparison
Olympus CV-170 vs Olympus OTV-S190 / CLV-S190: Which System is Right for You?
When choosing an endoscopy system, two of the most popular options are the Olympus CV-170 and the Olympus OTV-S190 with CLV-S190 light source. Both deliver HD video and Narrow Band Imaging (NBI), but they are built for different clinical settings. This comparison highlights the main differences so you can select the best fit for your practice.
Olympus CV-170 – Compact LED-Based Video Processor
The Olympus CV-170 combines an HD video processor and LED light source into a single compact unit. It is designed for ENT, urology, GI, and outpatient centers where space, ease of use, and low maintenance are critical.
Key Features
-
Integrated LED light source (long life, low maintenance)
-
Supports HD video and NBI imaging
-
Ideal for clinics, procedure rooms, and mobile setups
-
Compact footprint with simplified outputs
-
Reduced cost of ownership thanks to LED technology
Olympus OTV-S190 + CLV-S190 – VISERA ELITE OR System
The OTV-S190 video processor paired with the CLV-S190 xenon light source is part of Olympus’s VISERA ELITE platform. This system is built for hospital operating rooms requiring maximum brightness, connectivity, and integration.
Key Features
-
300W xenon light source for intense illumination
-
HD video and enhanced NBI performance with brighter, sharper imaging
-
Advanced outputs: HD-SDI, DVI, analog
-
USB capture for still images and video recording
-
Supports a broad range of Olympus rigid and flexible scopes
-
Designed for multi-room OR integration and teaching hospitals
Side-by-Side Comparison
Feature | Olympus CV-170 | Olympus OTV-S190 + CLV-S190 |
---|---|---|
Imaging | HD video + NBI | HD video + enhanced NBI |
Light Source | Integrated LED | Separate 300W Xenon |
Design | All-in-one compact unit | Modular two-box system |
Connectivity | Standard outputs | Advanced: HD-SDI, DVI, USB capture |
Use Case | Clinics, outpatient centers | Hospital ORs, teaching institutions |
Maintenance | LED = minimal upkeep | Xenon lamp replacements required |
Which One Should You Choose?
-
Choose Olympus CV-170 if you need a cost-effective, compact, and low-maintenance system for a clinic, ENT office, or outpatient procedure room.
-
Choose Olympus OTV-S190 + CLV-S190 if you require maximum brightness, advanced connectivity, and OR integration for hospital or teaching environments.
Both systems deliver Olympus-quality imaging, but your choice depends on your setting, budget, and integration needs.